CLIMATE CONTROL (8 artikelen)
Prev[1]Next
Toon: Lijst Sorteer op:
EECBO04A1KNX UNIVERSAL MODULE 4 OUT he DIN RAIL 4 Output Module EECBO04A01KNX is an EIB/KNX DIN rail mounting device useful to interface loads (e.g. lamps) for any kind of applications.
Device 4 outputs on board can be configured:
• Each output can be configured independently for load control (R1 to R4)
• Each output can be configured independently for ON/ OFF or continuous switching (PWM) for Electric valves (solenoid actuators) (EV1 to EV4)
• Outputs can be configured in pairs for the management of roller shutters and blinds; up to 2 channels (Channels A to B)
• Outputs can be configured in pairs for management of Motor Reductor or for solenoid valves with 3-point control or for ventilating grille; up to 2 channels (Channels A to B)
Output / Function OUT 1 ? (up) OUT 3 ? (up)
Output / Function OUT 2 ?(down) OUT 4 ?(down)
Device is intended to be installed on DIN rail. 1
EECBO04A1KNX
EECBO08A01KNX UNIVERSAL MODULE 8 OUT  1
EECBO08A01KNX
EECBO16F01KNX UNIVERSAL  MODULE 16 OUT PLUS - WITH MANUAL CONTROL  1
EECBO16F01KNX-SD UNIVERSAL  MODULE 16 OUT PLUS - WITH MANUAL CONTROL+SD CARD  1
EECIO32D01KNX INWALL MODULE 3 IN / 2 OUT IO32D01KNX module includes: • 2 digital inputs • 1 analog input • 2 relay output (bistable) Digital inputs are intended to be connected to free potential contacts and can interface sensors, traditional buttons, etc; they can be used to on/off commands, dimming, shutter control, scene recall and control, sequences of 3 objects. Analog input, can manage one temperature probe (with On/Off threshold) or one thermostats to control heating and cooling equipments, valves, 2 and 4 pipes fan coils; etc.. Analog input, alternatively to the temperature sensor, can manage a Infrared Receiver (IRX) in order to forward to the bus up to 8 channel coming from a Infrared Remote Control (IRC) with on/off commands, scenes, sequences of 2 objects, dimmer and shutter. Outputs include switching function with timed delays, staircase function, scene recall, lock or logic function. • Each output can be configured independently for load control (2 independent channels) Device 2 outputs on board can be configured: • Each output can be configured independently for ON / OFF or continuous switching (PWM) for Electric valves (solenoid actuators) (2 independent channels) • Outputs can be configured in pairs for the management of roller shutters and blinds; (1 channel) The device is equipped with KNX communication interface. 1
EECIO44B02KNX-C MULTIIFUNCTIONAL  4 IN / 4 OUT – CAPACITIVE LOADS The DIN RAIL 4 Input / 4 Output Module IO44B02KNX is an EIB/KNX DIN rail mounting device useful to interface commands (e.g. push buttons) or loads (e.g. lamps) for any kind of applications. The device is equipped with 4 binary inputs (potential free) and 4 binary relay outputs. Inputs can be connected to conventional switching devices, e.g. push buttons, switches, floating contacts, for switching functions with pulse edge evaluation (e.g. rising or falling edge, toggle, etc…). Inputs can be configured with ETS SW, as output channels to drive LED in synoptic monitoring panels. Inputs can be used to for on/off commands, dimming, shutter control, scene recall and control. Outputs include switching function, scene recall, control logic function; timing function and a delay on activation or deactivation can be enabled. Outoputs can act as interlocked channels; this function can be used to drive fan coils with 2-pipe / 3 speed or 4-pipe / 2 speed. Device is intended to be installed on DIN rail. 1
EECIO44E01KNX UNIVERSAL MODULE 4 IN / 4 OUT – LOADS/SHUTTERS/VALVES The DIN RAIL 4 Input / 4 Output Module IO44E01KNX is an EIB/KNX DIN rail mounting device useful to interface commands (e.g. push buttons) or loads (e.g. lamps) for any kind of applications. The device is equipped with 4 binary inputs (potential free) and 4 binary relay outputs. Inputs can be connected to conventional switching devices, e.g. push buttons, switches, floating contacts, for switching functions with pulse edge evaluation (e.g. rising or falling edge, toggle…). Inputs can be configured with ETS SW, as output to drive Leds. Inputs can be used to for on/off commands, dimming, shutter control, scene recall and control; outputs include switching function, scene recall and control logic function. Device 4 outputs on board can be configured: • Each output can be configured independently for load control (R1 to R4) • Each output can be configured independently for ON / OFF or continuous switching (PWM) for Electric valves (solenoid actuators) (EV1 to EV4) • Outputs can be configured in pairs for the management of roller shutters and blinds; up to 2 channels (Channels A to B) • Outputs can be configured in pairs for management of Motor Reductor or for solenoid valves with 3-point control or for ventilating grille; up to 2 channels (Channels A to B) 1
EECTC17B01KNX FANCOIL CONTROLLER 0-10v The Fan Coil Unit Controller is used to control fan coil units, floor heating or switch actuators. Depending on the design of the device, fan coil units are used in 2-pipe or 4- pipe systems. It controls up to 3 fan speeds (Relay or 0- 10V outputs) as well as heating or cooling valves (Proportional or electrothermal valve) respectively. The mode of control is based on two-step control or a time- discrete PI controller with setpoint/actual value comparison. The valves and the fan can be regulated directly by devices via the closed loop of this controller. When the Fan Coil Unit Controller is used in floor heating, it can control up to seven channel. All of the floor heating channel control is used a time-discrete PI controller with setpoint / actual value comparison. 1
EECTC17B01KNX
Prev[1]Next